{"id":17342,"date":"2026-02-26T12:43:07","date_gmt":"2026-02-26T12:43:07","guid":{"rendered":"http:\/\/localhost:8080\/wordpress\/?page_id=17342"},"modified":"2026-04-25T10:25:05","modified_gmt":"2026-04-25T10:25:05","slug":"corrosion-test","status":"publish","type":"page","link":"https:\/\/transasialab.com\/new\/corrosion-test\/","title":{"rendered":"Corrosion Test"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"17342\" class=\"elementor elementor-17342\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c30ea7a e-con-full e-flex e-con e-parent\" data-id=\"c30ea7a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-77f2123 elementor-widget elementor-widget-banner-slider\" data-id=\"77f2123\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"banner-slider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\r\n        <div class=\"swiper banner-swiper banner-slider style-three\"\r\n             data-swiper='{&quot;spaceBetween&quot;:0,&quot;slidesPerView&quot;:1,&quot;loop&quot;:true,&quot;autoHeight&quot;:true,&quot;effect&quot;:&quot;fade&quot;,&quot;fadeEffect&quot;:{&quot;crossFade&quot;:true},&quot;navigation&quot;:{&quot;nextEl&quot;:&quot;.swiper-button-next&quot;,&quot;prevEl&quot;:&quot;.swiper-button-prev&quot;},&quot;autoplay&quot;:{&quot;delay&quot;:7000},&quot;speed&quot;:2500}'>\r\n            <div class=\"swiper-wrapper\">\r\n\r\n                                    <div class=\"swiper-slide active\">\r\n                        \r\n<div class=\"slider-img\" style=\"background-image: url('http:\/\/localhost:8080\/wordpress\/wp-content\/uploads\/2026\/04\/A_hyperrealistic_ultracinematic_2026010616-5.png'); background-position: right center;\"><\/div>\r\n        <div class=\"slider-overlay\" style=\"background: linear-gradient(to right, #f2f3f3 10%, rgba(255,255,255,0.8) 20%, rgba(255,255,255,0) 80%);\"><\/div>\r\n    <div class=\"banner-content\">\r\n    <div class=\"banner-text\">\r\n            <h6 class=\"mb-3 animate-circle-scale delay-500\">Welcome To Trans Asia<\/h6>\r\n    \r\n    <h1 class=\"hero-heading mb-4 animate-scale-clip-bottom delay-1000\">\r\n                    Measure Metal Degradation                    <\/h1>\r\n\r\n            <div class=\"animate-clip delay-1500\">\r\n        <p>Precise corrosion testing to evaluate material durability, identify degradation risks, and ensure long-term performance in harsh industrial environments.<\/p>        <\/div>\r\n    \r\n    <div class=\"banner-btn animate-fade-up delay-2000\">\r\n                        <a class=\"themeht-btn primary-btn\"\r\n               href=\"#main-section\">\r\n                <span class=\"btn-icon\"><i class=\"flaticon-right-arrow-1\"><\/i><i class=\"flaticon-right-arrow-1\"><\/i><\/span>\r\n                <span class=\"btn-text\">Get Started<\/span>\r\n            <\/a>\r\n                                <\/div>\r\n    <\/div>\r\n<\/div>\r\n                    <\/div>\r\n                                    <div class=\"swiper-slide\">\r\n                        \r\n<div class=\"slider-img\" style=\"background-image: url('http:\/\/localhost:8080\/wordpress\/wp-content\/uploads\/2026\/04\/Trans-Asia-Performing-Corrosion-Test-IGC-Test-1.jpeg'); background-position: right center;\"><\/div>\r\n        <div class=\"slider-overlay\" style=\"background: linear-gradient(to right, #f2f3f3 10%, rgba(255,255,255,0.8) 20%, rgba(255,255,255,0) 80%);\"><\/div>\r\n    <div class=\"banner-content\">\r\n    <div class=\"banner-text\">\r\n            <h6 class=\"mb-3 animate-circle-scale delay-500\">We Simulate, We Test<\/h6>\r\n    \r\n    <h1 class=\"hero-heading mb-4 animate-scale-clip-bottom delay-1000\">\r\n                    Corrosion reveals Compatibility                    <\/h1>\r\n\r\n            <div class=\"animate-clip delay-1500\">\r\n        <p>Advanced analysis detects corrosion mechanisms early, helping prevent failures, extend asset life, and maintain safety and compliance.<\/p>        <\/div>\r\n    \r\n    <div class=\"banner-btn animate-fade-up delay-2000\">\r\n                        <a class=\"themeht-btn primary-btn\"\r\n               href=\"#main-section\">\r\n                <span class=\"btn-icon\"><i class=\"flaticon-right-arrow-1\"><\/i><i class=\"flaticon-right-arrow-1\"><\/i><\/span>\r\n                <span class=\"btn-text\">Discover More<\/span>\r\n            <\/a>\r\n                                <\/div>\r\n    <\/div>\r\n<\/div>\r\n                    <\/div>\r\n                \r\n            <\/div>\r\n            <div class=\"banner-swiper-buttons\">\r\n                <div class=\"swiper-button-next\"><\/div>\r\n                <div class=\"swiper-button-prev\"><\/div>\r\n            <\/div>\r\n        <\/div>\r\n\r\n        \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1de2aba e-flex e-con-boxed e-con e-parent\" data-id=\"1de2aba\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-9542f61 e-con-full e-flex e-con e-child\" data-id=\"9542f61\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-b8967d5 e-con-full primary-bg e-flex e-con e-child\" data-id=\"b8967d5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-be956d5 elementor-widget elementor-widget-progress\" data-id=\"be956d5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"progress.default\">\n\t\t\t\t\t\t\t\t<span class=\"elementor-title\" id=\"elementor-progress-bar-be956d5\">\n\t\t\t\tIndustrial \t\t\t<\/span>\n\t\t\n\t\t<div aria-labelledby=\"elementor-progress-bar-be956d5\" class=\"elementor-progress-wrapper\" role=\"progressbar\" aria-valuemin=\"0\" aria-valuemax=\"100\" aria-valuenow=\"74\">\n\t\t\t<div class=\"elementor-progress-bar\" data-max=\"74\">\n\t\t\t\t<span class=\"elementor-progress-text\"><\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-progress-percentage\">74%<\/span>\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c22b878 elementor-widget elementor-widget-progress\" data-id=\"c22b878\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"progress.default\">\n\t\t\t\t\t\t\t\t<span class=\"elementor-title\" id=\"elementor-progress-bar-c22b878\">\n\t\t\t\tInfrastructure\t\t\t<\/span>\n\t\t\n\t\t<div aria-labelledby=\"elementor-progress-bar-c22b878\" class=\"elementor-progress-wrapper\" role=\"progressbar\" aria-valuemin=\"0\" aria-valuemax=\"100\" aria-valuenow=\"92\">\n\t\t\t<div class=\"elementor-progress-bar\" data-max=\"92\">\n\t\t\t\t<span class=\"elementor-progress-text\"><\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-progress-percentage\">92%<\/span>\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-05ab840 elementor-widget elementor-widget-progress\" data-id=\"05ab840\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"progress.default\">\n\t\t\t\t\t\t\t\t<span class=\"elementor-title\" id=\"elementor-progress-bar-05ab840\">\n\t\t\t\tSustainable Projects\t\t\t<\/span>\n\t\t\n\t\t<div aria-labelledby=\"elementor-progress-bar-05ab840\" class=\"elementor-progress-wrapper\" role=\"progressbar\" aria-valuemin=\"0\" aria-valuemax=\"100\" aria-valuenow=\"82\">\n\t\t\t<div class=\"elementor-progress-bar\" data-max=\"82\">\n\t\t\t\t<span class=\"elementor-progress-text\"><\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-progress-percentage\">82%<\/span>\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-043d8b1 e-con-full white-bg e-flex e-con e-child\" data-id=\"043d8b1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-364a2cd e-grid e-con-full e-con e-child\" data-id=\"364a2cd\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d8409cd elementor-widget elementor-widget-feature\" data-id=\"d8409cd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"feature.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\r\n                    \r\n                            <div class=\"featured-item style-2   \">\r\n                                                              <div class=\"featured-img \"><img decoding=\"async\" src=\"https:\/\/transasialab.com\/new\/wp-content\/uploads\/2025\/12\/conveyor.png\" alt=\"Icon\"><\/div>\r\n                                                        <div class=\"featured-title\">\r\n                  <h4>Fabrication<\/h4>\r\n                <\/div>\r\n                                \r\n        <\/div>\r\n                            \r\n                        \r\n            \r\n        \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-43bfc49 elementor-widget elementor-widget-feature\" data-id=\"43bfc49\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"feature.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\r\n                    \r\n                            <div class=\"featured-item style-2   \">\r\n                                                              <div class=\"featured-img \"><img decoding=\"async\" src=\"https:\/\/transasialab.com\/new\/wp-content\/uploads\/2025\/12\/architect.png\" alt=\"Icon\"><\/div>\r\n                                                        <div class=\"featured-title\">\r\n                  <h4>Construction<\/h4>\r\n                <\/div>\r\n                                \r\n        <\/div>\r\n                            \r\n                        \r\n            \r\n        \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bc045d9 elementor-widget elementor-widget-feature\" data-id=\"bc045d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"feature.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\r\n                    \r\n                            <div class=\"featured-item style-2   \">\r\n                                                              <div class=\"featured-img \"><img decoding=\"async\" src=\"https:\/\/transasialab.com\/new\/wp-content\/uploads\/2025\/12\/fast-delivery.png\" alt=\"Icon\"><\/div>\r\n                                                        <div class=\"featured-title\">\r\n                  <h4>On-Time Delivery<\/h4>\r\n                <\/div>\r\n                                \r\n        <\/div>\r\n                            \r\n                        \r\n            \r\n        \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9be5dee e-flex e-con-boxed e-con e-parent\" data-id=\"9be5dee\" data-element_type=\"container\" data-e-type=\"container\" id=\"main-section\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-5d54de2 e-con-full e-flex e-con e-child\" data-id=\"5d54de2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-95eaa8a elementor-widget elementor-widget-title\" data-id=\"95eaa8a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"theme-title style-1  \">\r\n                            <div class=\"ht-subtitle\"><h6>Corrosion Test<\/h6><\/div>\r\n                        <h2 class=\"text-anime-style\">Detect corrosion early, prevent costly <span class=\"title-sub\">failures<\/span><\/h2>\r\n            <div><\/div>\r\n        <\/div>\r\n        \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3cd8bfe elementor-drop-cap-yes elementor-drop-cap-view-default elementor-widget elementor-widget-text-editor\" data-id=\"3cd8bfe\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;drop_cap&quot;:&quot;yes&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Corrosion testing is essential to evaluate how materials behave in aggressive environments and to predict their long-term performance. At <strong data-start=\"138\" data-end=\"176\">Trans Asia Industrial Laboratories<\/strong>, we provide comprehensive corrosion testing services to help industries identify degradation mechanisms, validate material selection, assess protective coatings, and prevent premature failures. Our testing supports compliance with international standards and enables informed decisions to enhance asset integrity, safety, and reliability across diverse applications.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-afeec40 e-con-full e-flex e-con e-child\" data-id=\"afeec40\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-29d8957 e-con-full e-flex e-con e-child\" data-id=\"29d8957\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bc43ba7 elementor-widget elementor-widget-image\" data-id=\"bc43ba7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"4000\" height=\"1844\" src=\"https:\/\/transasialab.com\/new\/wp-content\/uploads\/2026\/04\/Chem-23.jpg\" class=\"attachment-full size-full wp-image-17770\" alt=\"\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2f42257 e-con-full e-flex e-con e-child\" data-id=\"2f42257\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-88c3183 elementor-widget elementor-widget-list_style\" data-id=\"88c3183\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"list_style.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\r\n        <!-- Start rendering the output -->\r\n        \r\n        <ul class=\"list-unstyled list-icon style-1\">\r\n            <li>\r\n            <i class=\"flaticon flaticon-check-mark-1\"><\/i>            Intergranular Corrosion (IGC) Testing for austenitic stainless steel as per ASTM A 262 Practice A, B and E        <\/li>\r\n            <li>\r\n            <i class=\"flaticon flaticon-check-mark-1\"><\/i>            Intergranular Corrosion (IGC) Testing for Nickel based alloys &amp; Inconel materials as per ASTM G 28        <\/li>\r\n            <li>\r\n            <i class=\"flaticon flaticon-check-mark-1\"><\/i>            Pitting Corrosion Testing as per ASTM G48 Method A &amp; C \/ ASTM A 923 Method C.        <\/li>\r\n            <li>\r\n            <i class=\"flaticon flaticon-check-mark-1\"><\/i>            Stress Corrosion Cracking (SCC) Testing as per NACE TM0177 Method A         <\/li>\r\n            <li>\r\n            <i class=\"flaticon flaticon-check-mark-1\"><\/i>            Four Point Bent Stress Corrosion Cracking (SCC) Testing as per EPC Publication 16\/G39\/NACE TM0177        <\/li>\r\n            <li>\r\n            <i class=\"flaticon flaticon-check-mark-1\"><\/i>            Hydrogen Induced Cracking (HIC) as per NACE TM 0284        <\/li>\r\n            <li>\r\n            <i class=\"flaticon flaticon-check-mark-1\"><\/i>            Stress-Oriented Hydrogen Induced Cracking (SOHIC) as per standard NACE MR0175\/ISO15156        <\/li>\r\n            <li>\r\n            <i class=\"flaticon flaticon-check-mark-1\"><\/i>            Salt Spray (Fog) Testing        <\/li>\r\n            <li>\r\n            <i class=\"flaticon flaticon-check-mark-1\"><\/i>            Detrimental Intermetallic Phase Test as per ASTM A923        <\/li>\r\n            <li>\r\n            <i class=\"flaticon flaticon-check-mark-1\"><\/i>            Corrosion Rate Measurement &amp; Evaluation        <\/li>\r\n    <\/ul>\r\n\r\n        <!-- End rendering the output -->\r\n\r\n\r\n\r\n        \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f4a404a e-con-full e-flex e-con e-child\" data-id=\"f4a404a\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-61aa4b9 e-con-full e-flex e-con e-child\" data-id=\"61aa4b9\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;position&quot;:&quot;absolute&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0456a67 elementor-widget__width-initial elementor-absolute elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"0456a67\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_position&quot;:&quot;absolute&quot;}\" data-widget_type=\"divider.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-73cea42 elementor-widget__width-initial elementor-absolute elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"73cea42\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_position&quot;:&quot;absolute&quot;}\" data-widget_type=\"divider.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-23a5c6a elementor-widget elementor-widget-image\" data-id=\"23a5c6a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"3103\" height=\"1327\" src=\"https:\/\/transasialab.com\/new\/wp-content\/uploads\/2026\/04\/Services-collage-6.jpg\" class=\"attachment-full size-full wp-image-17838\" alt=\"corrosion test, HIC test, hydrogen induced cracking, SSC test, stress corrosion cracking\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2464530 primary-bg e-con-full e-flex e-con e-parent\" data-id=\"2464530\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-e504b86 e-con-full e-flex e-con e-child\" data-id=\"e504b86\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-200bedb elementor-widget__width-initial elementor-widget elementor-widget-title\" data-id=\"200bedb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"theme-title style-1 text-white text-center\">\r\n                            <div class=\"ht-subtitle\"><h6>Corrosion Test <\/h6><\/div>\r\n                        <h2 class=\"text-anime-style\">Expert Corrosion Test Services for <span class=\"title-sub\">Every Project<\/span><\/h2>\r\n            <div><\/div>\r\n        <\/div>\r\n        \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-078e290 e-grid e-con-full e-con e-child\" data-id=\"078e290\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-40bff46 elementor-widget elementor-widget-ht-service\" data-id=\"40bff46\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"ht-service.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"row  our-service-grid\" style=\"margin-left:-15px; margin-right:-15px;\"><div class=\"col-lg-6\" style=\"padding-left:15px; padding-right:15px; margin-bottom:30px;\"><div class=\"service-item style-4\">\r\n                <div class=\"service-image\"><img decoding=\"async\" src=\"http:\/\/localhost:8080\/wordpress\/wp-content\/uploads\/2026\/04\/Trans-Asia-Performing-Corrosion-Test-IGC-Test-1.jpeg\" title=\"\" alt=\"\" loading=\"lazy\" \/><\/div>\r\n            \r\n    <div class=\"service-desc\">\r\n\r\n                <div class=\"service-icon\">\r\n                <i aria-hidden=\"true\" class=\"flaticon flaticon-corrosive\"><\/i>            <\/div>\r\n            \r\n       \r\n\r\n            <div class=\"service-title\">\r\n            <h4>\r\n                <a href=\"http:\/\/localhost:8080\/wordpress\/corrosion-test\/#intergranular-corrosion-testing\" \r\n                   target=\"_self\">\r\n                    Intergranular Corrosion Testing                <\/a>\r\n            <\/h4>\r\n        <\/div>\r\n    \r\n            <p style=\"-webkit-line-clamp: 2;\">Intergranular corrosion (IGC) is a localized form of attack that progresses along the grain boundaries of metallic materials, often leading to rapid loss of mechanical strength and ductility.<\/p>\r\n    \r\n            <a href=\"http:\/\/localhost:8080\/wordpress\/corrosion-test\/#intergranular-corrosion-testing\"\r\n           class=\"link-btn\"\r\n           target=\"_self\">\r\n            Explore Service <i class=\"flaticon flaticon-right-arrow-1\"><\/i>\r\n        <\/a>\r\n        <\/div>\r\n<\/div>\r\n<\/div><div class=\"col-lg-6\" style=\"padding-left:15px; padding-right:15px; margin-bottom:30px;\"><div class=\"service-item style-4\">\r\n                <div class=\"service-image\"><img decoding=\"async\" width=\"600\" height=\"335\" src=\"https:\/\/transasialab.com\/new\/wp-content\/uploads\/2026\/04\/Trans-Asia-Performing-Corrosion-Test-Pitting-Corrosion-Test-2.jpeg\" class=\"attachment-renvo-600x500 size-renvo-600x500 wp-image-17843\" alt=\"\" \/><\/div>\r\n            \r\n    <div class=\"service-desc\">\r\n\r\n                <div class=\"service-icon\">\r\n                <i aria-hidden=\"true\" class=\"flaticon flaticon-corrosive\"><\/i>            <\/div>\r\n            \r\n       \r\n\r\n            <div class=\"service-title\">\r\n            <h4>\r\n                <a href=\"http:\/\/localhost:8080\/wordpress\/corrosion-test\/#pitting-corrosion-testing\" \r\n                   target=\"_self\">\r\n                    Pitting Corrosion Testing                <\/a>\r\n            <\/h4>\r\n        <\/div>\r\n    \r\n            <p style=\"-webkit-line-clamp: 2;\">We provide specialized pitting corrosion testing to evaluate material performance, verify alloy quality, and ensure suitability for aggressive service environments.<\/p>\r\n    \r\n            <a href=\"http:\/\/localhost:8080\/wordpress\/corrosion-test\/#pitting-corrosion-testing\"\r\n           class=\"link-btn\"\r\n           target=\"_self\">\r\n            Explore Service <i class=\"flaticon flaticon-right-arrow-1\"><\/i>\r\n        <\/a>\r\n        <\/div>\r\n<\/div>\r\n<\/div><div class=\"col-lg-6\" style=\"padding-left:15px; padding-right:15px; margin-bottom:30px;\"><div class=\"service-item style-4\">\r\n                <div class=\"service-image\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"335\" src=\"https:\/\/transasialab.com\/new\/wp-content\/uploads\/2026\/04\/HIC-Test-Vessel-for-loading.jpg\" class=\"attachment-renvo-600x500 size-renvo-600x500 wp-image-17871\" alt=\"\" \/><\/div>\r\n            \r\n    <div class=\"service-desc\">\r\n\r\n                <div class=\"service-icon\">\r\n                <i aria-hidden=\"true\" class=\"flaticon flaticon-corrosive\"><\/i>            <\/div>\r\n            \r\n       \r\n\r\n            <div class=\"service-title\">\r\n            <h4>\r\n                <a href=\"http:\/\/localhost:8080\/wordpress\/corrosion-test\/#hydrogen-induced-cracking-testing\" \r\n                   target=\"_self\">\r\n                    Hydrogen Induced Cracking (HIC) Testing                <\/a>\r\n            <\/h4>\r\n        <\/div>\r\n    \r\n            <p style=\"-webkit-line-clamp: 2;\">Atomic hydrogen generated during corrosion diffuses into the metal and accumulates at internal defects such as inclusions or laminations, leading to the formation of internal cracks without external stress.<\/p>\r\n    \r\n            <a href=\"http:\/\/localhost:8080\/wordpress\/corrosion-test\/#hydrogen-induced-cracking-testing\"\r\n           class=\"link-btn\"\r\n           target=\"_self\">\r\n            Explore Service <i class=\"flaticon flaticon-right-arrow-1\"><\/i>\r\n        <\/a>\r\n        <\/div>\r\n<\/div>\r\n<\/div><div class=\"col-lg-6\" style=\"padding-left:15px; padding-right:15px; margin-bottom:30px;\"><div class=\"service-item style-4\">\r\n                <div class=\"service-image\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"338\" src=\"https:\/\/transasialab.com\/new\/wp-content\/uploads\/2026\/01\/A_hyperrealistic_ultracinematic_2026010616-6.png\" class=\"attachment-renvo-600x500 size-renvo-600x500 wp-image-16939\" alt=\"\" \/><\/div>\r\n            \r\n    <div class=\"service-desc\">\r\n\r\n                <div class=\"service-icon\">\r\n                <i aria-hidden=\"true\" class=\"flaticon flaticon-corrosive\"><\/i>            <\/div>\r\n            \r\n       \r\n\r\n            <div class=\"service-title\">\r\n            <h4>\r\n                <a href=\"http:\/\/localhost:8080\/wordpress\/corrosion-test\/#sulfide-stress-corrosion-cracking-testing\" \r\n                   target=\"_self\">\r\n                    Stress Corrosion Cracking (SSCC) Testing                <\/a>\r\n            <\/h4>\r\n        <\/div>\r\n    \r\n            <p style=\"-webkit-line-clamp: 2;\">We provide specialized pitting corrosion testing to evaluate material performance, verify alloy quality, and ensure suitability for aggressive service environments.<\/p>\r\n    \r\n            <a href=\"http:\/\/localhost:8080\/wordpress\/corrosion-test\/#sulfide-stress-corrosion-cracking-testing\"\r\n           class=\"link-btn\"\r\n           target=\"_self\">\r\n            Explore Service <i class=\"flaticon flaticon-right-arrow-1\"><\/i>\r\n        <\/a>\r\n        <\/div>\r\n<\/div>\r\n<\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-69935bc e-con-full primary-bg e-flex e-con e-parent\" data-id=\"69935bc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5977906 elementor-widget elementor-widget-marquee-animation\" data-id=\"5977906\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"marquee-animation.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t    <div class=\"marquee-wrap style2 pause-on-hover\">\r\n        <div class=\"marquee-inner \" style=\"--scroll-speed: 60s;\">\r\n            <div class=\"marquee-content\">\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Metal<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Alloy<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>NDT<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Engineering<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Shut Down<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Heat Treatment<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Inspection<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>PAUT<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Corrosion<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Failure Analysis<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                <!-- Duplicate the list for seamless looping -->\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Metal<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Alloy<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>NDT<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Engineering<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Shut Down<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Heat Treatment<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Inspection<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>PAUT<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Corrosion<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Failure Analysis<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/div>\r\n    \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6a692d9 e-flex e-con-boxed e-con e-parent\" data-id=\"6a692d9\" data-element_type=\"container\" data-e-type=\"container\" id=\"intergranular-corrosion-testing\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-f0dd47d e-con-full e-flex e-con e-child\" data-id=\"f0dd47d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-bee8e7d e-con-full e-flex e-con e-child\" data-id=\"bee8e7d\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-93259b7 e-con-full e-flex e-con e-child\" data-id=\"93259b7\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;position&quot;:&quot;absolute&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fe0b915 elementor-widget__width-initial elementor-absolute elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"fe0b915\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_position&quot;:&quot;absolute&quot;}\" data-widget_type=\"divider.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f29a16e elementor-widget__width-initial elementor-absolute elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"f29a16e\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_position&quot;:&quot;absolute&quot;}\" data-widget_type=\"divider.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7d8738e elementor-widget elementor-widget-image\" data-id=\"7d8738e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"http:\/\/localhost:8080\/wordpress\/wp-content\/uploads\/2026\/04\/Trans-Asia-Performing-Corrosion-Test-IGC-Test-1.jpeg\" title=\"\" alt=\"\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-07e9570 elementor-widget elementor-widget-title\" data-id=\"07e9570\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"theme-title style-1  \">\r\n                            <div class=\"ht-subtitle\"><h6>Corrosion Test<\/h6><\/div>\r\n                        <h2 class=\"text-anime-style\">Intergranular Corrosion (IGC) <span class=\"title-sub\">Testing<\/span><\/h2>\r\n            <div><\/div>\r\n        <\/div>\r\n        \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7eec8a1 elementor-drop-cap-yes elementor-drop-cap-view-default elementor-widget elementor-widget-text-editor\" data-id=\"7eec8a1\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;drop_cap&quot;:&quot;yes&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Intergranular corrosion (IGC) is a localized form of attack that progresses along the grain boundaries of metallic materials, often leading to rapid loss of mechanical strength and ductility. This phenomenon is commonly associated with chromium carbide precipitation in stainless steels, where exposure to temperatures between <strong data-start=\"454\" data-end=\"473\">500\u00b0C and 800\u00b0C<\/strong>\u2014such as during welding\u2014causes chromium depletion at grain boundaries. As a result, these regions become more susceptible to corrosion compared to the surrounding material.<\/p><p>At <strong data-start=\"650\" data-end=\"688\">Trans Asia Industrial Laboratories<\/strong>, we specialize in detecting and evaluating IGC to support industries in ensuring material integrity, process control, and long-term reliability.<\/p><p data-section-id=\"1gf5r4u\" data-start=\"840\" data-end=\"875\"><span role=\"text\"><strong data-start=\"843\" data-end=\"875\">Materials Susceptible to IGC<\/strong><\/span><\/p><p>Intergranular corrosion can affect a range of crystalline materials, particularly:<\/p><ul><li>Steels (especially austenitic stainless steels)<\/li><li>Brasses<\/li><li>Bronzes<\/li><li>Aluminum alloys<\/li><\/ul><p data-section-id=\"1rtsw3a\" data-start=\"1470\" data-end=\"1498\"><span role=\"text\"><strong data-start=\"1473\" data-end=\"1498\">IGC Testing Standards<\/strong><\/span><\/p><p>Trans Asia Industrial Laboratories LLC conducts IGC testing in accordance with internationally recognized standards, including:<\/p><p data-section-id=\"1lu8vlz\" data-start=\"1600\" data-end=\"1682\"><span role=\"text\"><strong data-start=\"1604\" data-end=\"1682\">ASTM A262 \u2013 Practices for Detecting Susceptibility to Intergranular Attack<\/strong><\/span><\/p><ul data-start=\"1684\" data-end=\"2226\"><li data-section-id=\"1s0ecii\" data-start=\"1684\" data-end=\"1944\"><p><strong data-start=\"1686\" data-end=\"1724\">Practice A \u2013 Oxalic Acid Etch Test<\/strong><\/p><p>ASTM A262 Practice A is a rapid screening method used to assess the susceptibility of austenitic stainless steels to intergranular corrosion. The test involves electrolytic etching of the specimen in a 10% oxalic acid solution, followed by microscopic examination of the grain boundary structure. Based on the etch pattern\u2014step, dual, or ditch\u2014the material\u2019s sensitization level is identified. This method is primarily used as a quick acceptance tool to determine whether further, more rigorous corrosion testing is required.<\/p><\/li><li data-section-id=\"2asvh6\" data-start=\"1946\" data-end=\"2226\"><p data-section-id=\"1n2zt7y\" data-start=\"673\" data-end=\"739\"><span role=\"text\"><strong data-start=\"677\" data-end=\"737\">Practice B \u2013 Ferric Sulfate\u2013Sulfuric Acid Test<\/strong><\/span><\/p><p>ASTM A262 Practice B is a quantitative test used to evaluate intergranular corrosion through weight loss measurement. The specimen is exposed to a boiling ferric sulfate\u2013sulfuric acid solution, promoting preferential attack along sensitized grain boundaries. After exposure, the material is cleaned and weighed to determine corrosion rate. This method provides measurable data on the degree of sensitization and is widely used for comparative analysis, material qualification, and quality control.<\/p><\/li><li><p><strong data-start=\"1948\" data-end=\"2005\">Practice E \u2013 Copper\u2013Copper Sulfate\u2013Sulfuric Acid Test<\/strong><\/p><p>ASTM A262 Practice E is a confirmatory method for detecting susceptibility to intergranular corrosion in austenitic stainless steels. The specimen is immersed in a boiling copper sulfate\u2013sulfuric acid solution and then subjected to a 180\u00b0 bend test. The presence of cracks or fissures along grain boundaries indicates susceptibility. This method evaluates the loss of ductility due to intergranular attack and is considered a reliable indicator of material performance under corrosive service conditions.<\/p><\/li><\/ul><p data-section-id=\"zhnifk\" data-start=\"1829\" data-end=\"1899\"><span role=\"text\"><strong data-start=\"1833\" data-end=\"1897\">ASTM G28 \u2013 Intergranular Corrosion Testing for Nickel Alloys<\/strong><\/span><\/p><p data-start=\"1900\" data-end=\"2443\">ASTM G28 is used to assess intergranular corrosion resistance in nickel-rich and high-performance alloys. The test typically involves exposing specimens to aggressive boiling acid solutions, followed by evaluation based on weight loss. It is particularly relevant for materials used in severe chemical and high-temperature environments. ASTM G28 helps determine alloy suitability, detect sensitization, and ensure compliance with industry standards, making it essential for critical applications in oil &amp; gas, petrochemical, and power sectors.<\/p><p data-section-id=\"1w9j2fl\" data-start=\"2273\" data-end=\"2303\"><span role=\"text\"><strong data-start=\"2277\" data-end=\"2303\">Why IGC Tests Matter<\/strong><\/span><\/p><p data-start=\"2304\" data-end=\"2377\">Together, <strong>A262 Practice A, B, E and G28<\/strong>\u00a0provide a comprehensive approach:<\/p><ul><li><strong data-start=\"2380\" data-end=\"2394\">Practice A<\/strong> offers a fast, economical screening method<\/li><li><strong>Practice B<\/strong> offers quantitative measure of corrosion.<\/li><li><strong data-start=\"2442\" data-end=\"2456\">Practice E<\/strong> delivers a reliable, performance-based confirmation<\/li><li><strong>ASTM G28<\/strong> determines alloy suitability and detects sensitiaztion.<\/li><\/ul><p data-start=\"2512\" data-end=\"2746\">At <strong data-start=\"2515\" data-end=\"2553\">Trans Asia Industrial Laboratories<\/strong>, these standardized testing methods ensure accurate assessment of material behavior, helping industries prevent failures, validate welding procedures, and maintain long-term asset reliability.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-dcc525e e-flex e-con-boxed e-con e-parent\" data-id=\"dcc525e\" data-element_type=\"container\" data-e-type=\"container\" id=\"pitting-corrosion-testing\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-eba5283 e-con-full e-flex e-con e-child\" data-id=\"eba5283\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-9bb7431 e-con-full e-flex e-con e-child\" data-id=\"9bb7431\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-61d1285 e-con-full e-transform e-flex e-con e-child\" data-id=\"61d1285\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;position&quot;:&quot;absolute&quot;,&quot;_transform_flipX_effect&quot;:&quot;transform&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2b82d0a elementor-widget__width-initial elementor-absolute elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"2b82d0a\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_position&quot;:&quot;absolute&quot;}\" data-widget_type=\"divider.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-92938b6 elementor-widget__width-initial elementor-absolute elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"92938b6\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_position&quot;:&quot;absolute&quot;}\" data-widget_type=\"divider.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e0235a e-transform elementor-widget elementor-widget-image\" data-id=\"3e0235a\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_transform_flipX_effect&quot;:&quot;transform&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"335\" src=\"https:\/\/transasialab.com\/new\/wp-content\/uploads\/2026\/04\/Trans-Asia-Performing-Corrosion-Test-Pitting-Corrosion-Test-3.jpeg\" class=\"attachment-renvo-600x600 size-renvo-600x600 wp-image-17850\" alt=\"\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e35b6a8 elementor-widget elementor-widget-title\" data-id=\"e35b6a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"theme-title style-1  \">\r\n                            <div class=\"ht-subtitle\"><h6>Corrosion Test<\/h6><\/div>\r\n                        <h2 class=\"text-anime-style\">Pitting Corrosion <span class=\"title-sub\">Testing<\/span><\/h2>\r\n            <div><\/div>\r\n        <\/div>\r\n        \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d773308 elementor-drop-cap-yes elementor-drop-cap-view-default elementor-widget elementor-widget-text-editor\" data-id=\"d773308\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;drop_cap&quot;:&quot;yes&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Pitting corrosion is a localized form of attack that leads to the formation of small, deep cavities on metal surfaces. Despite minimal overall material loss, pitting can significantly reduce structural integrity and lead to sudden failures, particularly in stainless steels and corrosion-resistant alloys. At <strong data-start=\"343\" data-end=\"381\">Trans Asia Industrial Laboratories<\/strong>, we provide specialized pitting corrosion testing to evaluate material performance, verify alloy quality, and ensure suitability for aggressive service environments.<\/p><p data-section-id=\"5k4q88\" data-start=\"554\" data-end=\"613\"><span role=\"text\"><strong data-start=\"557\" data-end=\"613\">ASTM G48 \u2013 Pitting Corrosion Testing (Methods A &amp; C)<\/strong><\/span><\/p><p>ASTM G48 is a widely recognized standard used to assess the resistance of stainless steels and related alloys to pitting and crevice corrosion in <strong data-start=\"761\" data-end=\"791\">chloride-rich environments<\/strong>.<\/p><p data-section-id=\"ouki3n\" data-start=\"794\" data-end=\"845\"><span role=\"text\"><strong data-start=\"798\" data-end=\"843\">Method A \u2013 Ferric Chloride Immersion Test<\/strong><\/span><\/p><p>In Method A, test specimens are immersed in a <strong data-start=\"892\" data-end=\"928\">ferric chloride (FeCl\u2083) solution<\/strong> at a controlled temperature for a specified duration. This highly aggressive environment promotes localized pitting on susceptible materials. After exposure, specimens are cleaned and evaluated for:<\/p><ul><li>Weight loss<\/li><li>Presence, depth, and density of pits<\/li><\/ul><p>This method is commonly used for <strong data-start=\"1227\" data-end=\"1298\">material qualification, comparative evaluation, and quality control<\/strong>.<\/p><p data-section-id=\"17t7jbb\" data-start=\"1306\" data-end=\"1366\"><span role=\"text\"><strong data-start=\"1310\" data-end=\"1364\">Method C \u2013 Critical Pitting Temperature (CPT) Test<\/strong><\/span><\/p><p>Method C determines the <strong data-start=\"1391\" data-end=\"1429\">Critical Pitting Temperature (CPT)<\/strong>\u2014the lowest temperature at which stable pitting initiates under standardized conditions. The specimen is exposed to ferric chloride solution while temperature is gradually increased until pitting is observed.<\/p><p>This test provides:<\/p><ul><li>A quantitative measure of pitting resistance<\/li><li>Comparative ranking of materials and alloys<\/li><li>Valuable data for material selection in harsh environments<\/li><\/ul><p data-section-id=\"1gdhwiz\" data-start=\"1833\" data-end=\"1906\"><span role=\"text\"><strong data-start=\"1836\" data-end=\"1906\">ASTM A923 Method C \u2013 Pitting Resistance of Duplex Stainless Steels<\/strong><\/span><\/p><p>ASTM A923 Method C is specifically designed to evaluate the <strong data-start=\"1968\" data-end=\"2044\">pitting corrosion resistance of duplex and super duplex stainless steels<\/strong>, particularly after heat treatment or fabrication processes.<\/p><p>In this method:<\/p><ul><li>Specimens are immersed in a ferric chloride solution under controlled conditions<\/li><li>The test assesses susceptibility to pitting associated with undesirable microstructural phases<\/li><li>Evaluation is based on weight loss and visual examination of pits<\/li><\/ul><p>This method is critical for ensuring that duplex stainless steels maintain their <strong data-start=\"2471\" data-end=\"2534\">intended corrosion resistance and microstructural integrity<\/strong>.<\/p><p data-section-id=\"76skm4\" data-start=\"2542\" data-end=\"2586\"><span role=\"text\"><strong data-start=\"2545\" data-end=\"2586\">Why Pitting Corrosion Testing Matters<\/strong><\/span><\/p><ul><li>Detects localized corrosion risks not visible through general inspection<\/li><li>Supports material selection and qualification for chloride environments<\/li><li>Ensures compliance with ASTM and international standards<\/li><li>Helps prevent unexpected failures in critical assets<\/li><\/ul><p>At <strong data-start=\"2880\" data-end=\"2918\">Trans Asia Industrial Laboratories<\/strong>, we combine standardized testing with expert metallurgical interpretation to deliver <strong data-start=\"3004\" data-end=\"3051\">accurate, reliable, and actionable insights<\/strong>, helping industries enhance durability, safety, and performance in demanding operating conditions.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-14906cb e-flex e-con-boxed e-con e-parent\" data-id=\"14906cb\" data-element_type=\"container\" data-e-type=\"container\" id=\"hydrogen-induced-cracking-testing\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-60144ba e-con-full e-flex e-con e-child\" data-id=\"60144ba\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-799aaf2 e-con-full e-flex e-con e-child\" data-id=\"799aaf2\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-3e395f5 e-con-full e-flex e-con e-child\" data-id=\"3e395f5\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;position&quot;:&quot;absolute&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1ff01c5 elementor-widget__width-initial elementor-absolute elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"1ff01c5\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_position&quot;:&quot;absolute&quot;}\" data-widget_type=\"divider.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9820681 elementor-widget__width-initial elementor-absolute elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"9820681\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_position&quot;:&quot;absolute&quot;}\" data-widget_type=\"divider.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7268d5e elementor-widget elementor-widget-image\" data-id=\"7268d5e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"216\" src=\"https:\/\/transasialab.com\/new\/wp-content\/uploads\/2026\/04\/HIC-Test-Preparation.jpg\" class=\"attachment-renvo-600x600 size-renvo-600x600 wp-image-17862\" alt=\"corrosion test, HIC test, hydrogen induced cracking, SSC test, stress corrosion cracking\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6c27ff2 elementor-widget elementor-widget-title\" data-id=\"6c27ff2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"theme-title style-1  \">\r\n                            <div class=\"ht-subtitle\"><h6>Corrosion Test<\/h6><\/div>\r\n                        <h2 class=\"text-anime-style\">Hydrogen Induced Cracking (HIC) <span class=\"title-sub\">Testing<\/span><\/h2>\r\n            <div><\/div>\r\n        <\/div>\r\n        \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cecb8ab elementor-drop-cap-yes elementor-drop-cap-view-default elementor-widget elementor-widget-text-editor\" data-id=\"cecb8ab\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;drop_cap&quot;:&quot;yes&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"48\" data-end=\"537\">Hydrogen Induced Cracking (HIC) is a critical damage mechanism that affects steels exposed to <strong data-start=\"142\" data-end=\"181\">wet H\u2082S (sour service) environments<\/strong>. Atomic hydrogen generated during corrosion diffuses into the metal and accumulates at internal defects such as inclusions or laminations, leading to the formation of <strong data-start=\"349\" data-end=\"392\">internal cracks without external stress<\/strong>. This can significantly compromise structural integrity and result in unexpected failures in pipelines, pressure vessels, and process equipment.<\/p><p data-start=\"539\" data-end=\"742\">At <strong data-start=\"542\" data-end=\"580\">Trans Asia Industrial Laboratories<\/strong>, we perform HIC testing in accordance with <strong data-start=\"624\" data-end=\"639\">NACE TM0284<\/strong>, helping industries evaluate material resistance and ensure suitability for sour service applications.<\/p><p data-section-id=\"1g0yqar\" data-start=\"749\" data-end=\"785\"><span role=\"text\"><strong data-start=\"752\" data-end=\"785\">NACE TM0284 \u2013 HIC Test Method<\/strong><\/span><\/p><p data-start=\"787\" data-end=\"914\">NACE TM0284 is the internationally recognized standard for assessing the susceptibility of steels to hydrogen-induced cracking.<\/p><p data-section-id=\"b3jcpp\" data-start=\"916\" data-end=\"938\"><span role=\"text\"><strong data-start=\"920\" data-end=\"938\">Test Procedure<\/strong><\/span><\/p><ul><li>Test specimens are immersed in a controlled acidic solution saturated with hydrogen sulfide (H\u2082S)<\/li><li>Exposure is typically conducted for 96 hours under standardized conditions<\/li><li>The environment promotes hydrogen generation and diffusion into the material<\/li><li>After exposure, specimens are sectioned and examined for internal cracking<\/li><\/ul><p data-section-id=\"gqziez\" data-start=\"1294\" data-end=\"1323\"><span role=\"text\"><strong data-start=\"1297\" data-end=\"1323\">Evaluation &amp; Reporting<\/strong><\/span><\/p><p data-start=\"1325\" data-end=\"1390\">Crack susceptibility is quantified using standardized parameters:<\/p><ul><li>Crack Length Ratio (CLR)<\/li><li>Crack Thickness Ratio (CTR)<\/li><li>Crack Sensitivity Ratio (CSR)<\/li><\/ul><p data-start=\"1499\" data-end=\"1655\">These values indicate the extent and severity of internal cracking and are compared against acceptance criteria based on project or industry specifications.<\/p><p data-section-id=\"1s18h9s\" data-start=\"107\" data-end=\"172\"><span role=\"text\"><strong data-start=\"111\" data-end=\"172\">Stress-Oriented Hydrogen Induced Cracking (SOHIC) Testing<\/strong><\/span><\/p><p data-start=\"174\" data-end=\"952\">Stress-Oriented Hydrogen Induced Cracking (SOHIC) is an advanced form of hydrogen damage characterized by <strong data-start=\"280\" data-end=\"356\">stepwise cracking aligned in the direction of applied or residual stress<\/strong>, often occurring in sour service environments. Unlike conventional HIC, SOHIC develops as interconnected crack arrays, significantly increasing the risk of sudden failure in pipelines and pressure equipment. At <strong data-start=\"568\" data-end=\"606\">Trans Asia Industrial Laboratories<\/strong>, SOHIC evaluation is conducted in line with <strong data-start=\"651\" data-end=\"691\">NACE MR0175 \/ ISO 15156 requirements<\/strong>, supporting material qualification for critical applications. This testing helps assess susceptibility under combined hydrogen exposure and stress conditions, ensuring enhanced reliability, safety, and long-term performance in demanding oil &amp; gas environments.<\/p><p data-section-id=\"k0zlak\" data-start=\"1662\" data-end=\"1681\"><span role=\"text\"><strong data-start=\"1665\" data-end=\"1681\">Applications<\/strong><\/span><\/p><ul><li>Carbon steels for oil &amp; gas pipelines<\/li><li>Pressure vessels and process equipment<\/li><li>Materials used in sour service environments<\/li><li>Qualification of plates, pipes, and weldments<\/li><\/ul><p data-section-id=\"10wzq\" data-start=\"1880\" data-end=\"1914\"><span role=\"text\"><strong data-start=\"1883\" data-end=\"1914\">Why HIC Testing is Critical<\/strong><\/span><\/p><ul><li>Ensures material suitability for H\u2082S-containing environments<\/li><li>Prevents subsurface cracking and sudden failures<\/li><li>Supports compliance with NACE, ISO, and project specifications<\/li><li>Enhances asset integrity, safety, and reliability<\/li><\/ul><p data-start=\"2177\" data-end=\"2430\">At <strong data-start=\"2180\" data-end=\"2218\">Trans Asia Industrial Laboratories<\/strong>, we combine advanced testing facilities with metallurgical expertise to deliver <strong data-start=\"2299\" data-end=\"2362\">accurate, reliable, and standards-compliant HIC evaluations<\/strong>, supporting safe and efficient operation in demanding environments.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a921e5f e-flex e-con-boxed e-con e-parent\" data-id=\"a921e5f\" data-element_type=\"container\" data-e-type=\"container\" id=\"sulfide-stress-corrosion-cracking-testing\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-72fd3fc e-con-full e-flex e-con e-child\" data-id=\"72fd3fc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-b089bde e-con-full e-flex e-con e-child\" data-id=\"b089bde\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t<div class=\"elementor-element elementor-element-0105df7 e-con-full e-transform e-flex e-con e-child\" data-id=\"0105df7\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;position&quot;:&quot;absolute&quot;,&quot;_transform_flipX_effect&quot;:&quot;transform&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9b8e076 elementor-widget__width-initial elementor-absolute elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"9b8e076\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_position&quot;:&quot;absolute&quot;}\" data-widget_type=\"divider.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-333390a elementor-widget__width-initial elementor-absolute elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"333390a\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_position&quot;:&quot;absolute&quot;}\" data-widget_type=\"divider.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3fd42c3 e-transform elementor-widget elementor-widget-image\" data-id=\"3fd42c3\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_transform_flipX_effect&quot;:&quot;transform&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"335\" src=\"https:\/\/transasialab.com\/new\/wp-content\/uploads\/2026\/04\/Sulfide-stress-cracking-test-jig-proof-ring.jpg\" class=\"attachment-renvo-600x600 size-renvo-600x600 wp-image-17872\" alt=\"\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fdb7a11 elementor-widget elementor-widget-title\" data-id=\"fdb7a11\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t        <div class=\"theme-title style-1  \">\r\n                            <div class=\"ht-subtitle\"><h6>Corrosion Test<\/h6><\/div>\r\n                        <h2 class=\"text-anime-style\">Sulfide Stress Corrosion Cracking (SSCC) <span class=\"title-sub\">Testing<\/span><\/h2>\r\n            <div><\/div>\r\n        <\/div>\r\n        \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eff8d1a elementor-drop-cap-yes elementor-drop-cap-view-default elementor-widget elementor-widget-text-editor\" data-id=\"eff8d1a\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;drop_cap&quot;:&quot;yes&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"57\" data-end=\"489\">Sulfide Stress Corrosion Cracking (SSCC) is a critical failure mechanism affecting steels exposed to <strong data-start=\"158\" data-end=\"218\">wet H\u2082S (sour service) environments under tensile stress<\/strong>. The combined action of hydrogen generated from corrosion and applied or residual stress can lead to sudden brittle cracking, even at stress levels below the material\u2019s yield strength. SSCC is a major concern in pipelines, pressure vessels, and oil &amp; gas infrastructure.<\/p><p data-start=\"491\" data-end=\"705\">At <strong data-start=\"494\" data-end=\"532\">Trans Asia Industrial Laboratories<\/strong>, we perform SSCC testing in accordance with <strong data-start=\"577\" data-end=\"592\">NACE TM0177<\/strong> and related industry standards to evaluate material resistance and ensure safe application in sour environments.<\/p><p data-section-id=\"n5aecj\" data-start=\"712\" data-end=\"754\"><span role=\"text\"><strong data-start=\"715\" data-end=\"754\">NACE TM0177 Method A \u2013 Tensile Test<\/strong><\/span><\/p><p data-start=\"756\" data-end=\"856\"><strong data-start=\"756\" data-end=\"768\">Method A<\/strong> is a widely used test to determine SSCC susceptibility under <strong data-start=\"830\" data-end=\"855\">constant tensile load<\/strong>.<\/p><p data-section-id=\"b3jcpp\" data-start=\"858\" data-end=\"880\"><span role=\"text\"><strong data-start=\"862\" data-end=\"880\">Test Procedure<\/strong><\/span><\/p><ul><li>Cylindrical tensile specimens are exposed to a sour environment (H\u2082S-saturated solution)<\/li><li>A constant load or stress (typically a percentage of yield strength) is applied<\/li><li>The specimen is maintained under these conditions for a specified duration or until failure<\/li><\/ul><p data-section-id=\"1x0uuy8\" data-start=\"1163\" data-end=\"1181\"><span role=\"text\"><strong data-start=\"1167\" data-end=\"1181\">Evaluation<\/strong><\/span><\/p><ul><li>Time to failure or survival duration<\/li><li>Presence of cracking or fracture<\/li><li>Determination of threshold stress levels for safe operation<\/li><\/ul><p data-start=\"1337\" data-end=\"1470\">This method provides direct insight into the material\u2019s ability to withstand <strong data-start=\"1414\" data-end=\"1469\">sustained tensile stress in sour service conditions<\/strong>.<span role=\"text\"><strong data-start=\"1480\" data-end=\"1547\">Four-Point Bend Test \u2013 EPC Publication \/ NACE TM0177 Adaptation<\/strong><\/span><\/p><p data-start=\"1549\" data-end=\"1737\">The <strong data-start=\"1553\" data-end=\"1583\">Four-Point Bend (FPB) test<\/strong> is used to assess SSCC resistance under <strong data-start=\"1624\" data-end=\"1653\">controlled bending stress<\/strong>, simulating real service conditions where residual or applied stresses are present.<\/p><p data-section-id=\"b3jcpp\" data-start=\"1739\" data-end=\"1761\"><span role=\"text\"><strong data-start=\"1743\" data-end=\"1761\">Test Procedure<\/strong><\/span><\/p><ul><li>Flat specimens are subjected to constant bending stress using a four-point loading fixture<\/li><li>The stressed samples are exposed to a H\u2082S-containing corrosive environment<\/li><li>The test is conducted over a defined exposure period<\/li><\/ul><p data-section-id=\"1x0uuy8\" data-start=\"2002\" data-end=\"2020\"><span role=\"text\"><strong data-start=\"2006\" data-end=\"2020\">Evaluation<\/strong><\/span><\/p><ul><li>Crack initiation and propagation<\/li><li>Visual and microscopic examination of affected regions<\/li><li>Assessment of material performance under combined stress and corrosive conditions<\/li><\/ul><p data-start=\"2212\" data-end=\"2319\">This method is particularly useful for evaluating <strong data-start=\"2262\" data-end=\"2318\">weldments, coatings, and surface-sensitive materials<\/strong>.<\/p><p data-section-id=\"k0zlak\" data-start=\"2326\" data-end=\"2345\"><span role=\"text\"><strong data-start=\"2329\" data-end=\"2345\">Applications<\/strong><\/span><\/p><ul><li>Oil &amp; gas pipelines and tubular products<\/li><li>Pressure vessels and process equipment<\/li><li>Welded structures and heat-affected zones (HAZ)<\/li><li>Materials intended for sour service environments<\/li><\/ul><p data-section-id=\"14g4hs4\" data-start=\"2548\" data-end=\"2583\"><span role=\"text\"><strong data-start=\"2551\" data-end=\"2583\">Why SSCC Testing is Critical<\/strong><\/span><\/p><ul><li>Prevents catastrophic brittle failures in H\u2082S environments<\/li><li>Supports compliance with NACE, ISO, and project specifications<\/li><li>Helps determine safe operating stress limits<\/li><li>Ensures material integrity and long-term reliability<\/li><\/ul><p data-start=\"2841\" data-end=\"3105\">At <strong data-start=\"2844\" data-end=\"2882\">Trans Asia Industrial Laboratories<\/strong>, we combine advanced testing infrastructure with metallurgical expertise to deliver <strong data-start=\"2967\" data-end=\"3017\">accurate, standards-compliant SSCC evaluations<\/strong>, helping industries mitigate risk and ensure safe operations in demanding environments.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6f22beb e-con-full e-flex e-con e-parent\" data-id=\"6f22beb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7a9ebe7 animated-slow elementor-widget elementor-widget-marquee-animation\" data-id=\"7a9ebe7\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;none&quot;}\" data-widget_type=\"marquee-animation.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t    <div class=\"marquee-wrap style1 pause-on-hover\">\r\n        <div class=\"marquee-inner \" style=\"--scroll-speed: 60s;\">\r\n            <div class=\"marquee-content\">\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Mechanical Test<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Failure Analysis<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>NDT<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Advanced NDT<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Inspection<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Heat Treatment<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                <!-- Duplicate the list for seamless looping -->\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Mechanical Test<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Failure Analysis<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>NDT<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Advanced NDT<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Inspection<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                                    <div class=\"marquee-text\">\r\n                        <span>Heat Treatment<\/span>\r\n                        <i aria-hidden=\"true\" class=\"flaticon flaticon-asterisk-1\"><\/i>                    <\/div>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/div>\r\n    \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\n    <div class=\"xs_social_share_widget xs_share_url after_content \t\tmain_content  wslu-style-1 wslu-share-box-shaped wslu-fill-colored wslu-none wslu-share-horizontal wslu-theme-font-no wslu-main_content\">\n\n\t\t\n        <ul>\n\t\t\t        <\/ul>\n    <\/div> \n","protected":false},"excerpt":{"rendered":"<p>Welcome To Trans Asia Measure Metal Degradation Precise corrosion testing to evaluate material durability, identify degradation risks, and ensure long-term performance in harsh industrial environments. Get Started We Simulate, We Test Corrosion reveals Compatibility Advanced analysis detects corrosion mechanisms early, helping prevent failures, extend asset life, and maintain safety and compliance. Discover More Industrial 74% [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-17342","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/transasialab.com\/new\/wp-json\/wp\/v2\/pages\/17342","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/transasialab.com\/new\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/transasialab.com\/new\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/transasialab.com\/new\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/transasialab.com\/new\/wp-json\/wp\/v2\/comments?post=17342"}],"version-history":[{"count":40,"href":"https:\/\/transasialab.com\/new\/wp-json\/wp\/v2\/pages\/17342\/revisions"}],"predecessor-version":[{"id":18185,"href":"https:\/\/transasialab.com\/new\/wp-json\/wp\/v2\/pages\/17342\/revisions\/18185"}],"wp:attachment":[{"href":"https:\/\/transasialab.com\/new\/wp-json\/wp\/v2\/media?parent=17342"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}